Experimental procedure
Source typeROTATING ANODE
Detector technologyAREA DETECTOR
Collection date1995-06-14
DetectorSIEMENS-NICOLET X100
Spacegroup nameP 31 2 1
Unit cell lengths96.800, 96.800, 106.300
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution5.000 - 2.600
R-factor0.2
Rwork0.200
RMSD bond length0.012
RMSD bond angle1.800

*

Data reduction softwareXDS
Phasing softwareX-PLOR
Refinement softwareX-PLOR
Data quality characteristics
 Overall
Rmerge0.053
Number of reflections18101
Completeness [%]82.1
Redundancy2.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

7.5

*

Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein7.5 (mg/ml)
21dropammonium sulfate1.0 (M)
31dropPEG4001 (%)
41dropHEPES0.05 (M)
51reservoirammonium sulfate2.0 (M)
61reservoirPEG4002 (%)
71reservoirHEPES0.1 (M)