Full Matrix Error Analysis of Carbonic Anhydrase

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL9-1
Synchrotron siteSSRL
BeamlineBL9-1
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date1999-06-01
DetectorMAR scanner 345 mm plate
Spacegroup nameP 1 21 1
Unit cell lengths42.064, 41.311, 71.868
Unit cell angles90.00, 104.23, 90.00
Refinement procedure
Resolution15.000 - 0.950
Rwork0.119
R-free0.14110
Structure solution methodisomorphous structure
Starting model (for MR)2cba
RMSD bond length0.030
RMSD bond angle0.048
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareSHELX
Refinement softwareSHELXL-97
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0000.920
High resolution limit [Å]0.9000.900
Rmerge0.0690.440
Number of reflections172463
<I/σ(I)>171.34
Completeness [%]98.096
Redundancy3.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5293ammonium sulfate, Tris-Cl, p-hydroxymercuribenzoate, DMSO, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218500