Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1LFY

OXY HEMOGLOBIN (84% RELATIVE HUMIDITY)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]298
Detector technologyIMAGE PLATE
DetectorRIGAKU
Wavelength(s)1.5418
Spacegroup nameP 41 21 2
Unit cell lengths53.600, 53.600, 193.300
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution20.000 - 3.300
R-factor0.208
Rwork0.208
R-free0.26100
RMSD bond length0.012
RMSD bond angle1.400
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareCNS (0.4)
Data quality characteristics
 Overall
High resolution limit [Å]3.300
Number of reflections3620
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1LIQUID DIFFUSION6.7298phosphate buffer, pH 6.7, LIQUID DIFFUSION at 298K

223790

PDB entries from 2024-08-14

PDB statisticsPDBj update infoContact PDBjnumon