1L8I
Dna Protection and Binding by E. Coli DPS Protein
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | MACSCIENCE |
Temperature [K] | 95 |
Detector technology | IMAGE PLATE |
Collection date | 1998-03-06 |
Detector | MAC Science DIP-2030 |
Wavelength(s) | 1.5418 |
Spacegroup name | P 32 |
Unit cell lengths | 90.536, 90.536, 226.079 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 29.860 - 3.000 |
R-factor | 0.202 |
Rwork | 0.202 |
R-free | 0.25000 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1f33 |
RMSD bond length | 0.008 |
RMSD bond angle | 1.200 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | CNS (1.0) |
Refinement software | CNS (1.0) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 90.000 | 3.110 |
High resolution limit [Å] | 3.000 | 3.000 |
Rmerge | 0.071 | 0.283 |
Number of reflections | 41406 | |
<I/σ(I)> | 10.7 | |
Completeness [%] | 99.4 | 97.9 |
Redundancy | 6.3 | 2.12 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.1 | 298 | 10MM MOPS, 100MM KCL, 10%GLYCEROL + 100MM TRISHCL, 100MM KCL, 10% GLYCEROL, 11% PEG 8000, AND 5MM DTT, pH 8.10, VAPOR DIFFUSION, SITTING DROP, temperature 298K |