Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1L2O

SCALLOP MYOSIN S1-ADP-p-PDM IN THE ACTIN-DETACHED CONFORMATION

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X26C
Synchrotron siteNSLS
BeamlineX26C
Temperature [K]100
Detector technologyCCD
Collection date1999-03-26
DetectorADSC QUANTUM 4
Wavelength(s)1.1
Spacegroup nameP 1
Unit cell lengths51.800, 57.000, 150.500
Unit cell angles95.60, 96.30, 101.50
Refinement procedure
Resolution54.160 - 2.800
R-factor0.28
Rwork0.280
R-free0.32700
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1kk8
RMSD bond length0.010
RMSD bond angle1.900
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareCNS (0.9)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]55.0002.980
High resolution limit [Å]2.8002.800
Number of reflections29564
<I/σ(I)>16
Completeness [%]74.424.4
Redundancy2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.5277PEG 20000, magnesium chloride, ethylene glycol, Tris HCl, ATPgammaS, pH 8.5, VAPOR DIFFUSION, SITTING DROP, temperature 277K

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon