1JV5
Anti-blood group A Fv
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | ENRAF-NONIUS |
| Temperature [K] | 300 |
| Detector technology | DIFFRACTOMETER |
| Collection date | 1994-10-15 |
| Detector | ENRAF-NONIUS FAST |
| Wavelength(s) | 1.54 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 51.710, 57.960, 83.580 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 6.000 - 2.200 |
| R-factor | 0.183 |
| Rwork | 0.183 |
| R-free | 0.22300 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.412 |
| Data reduction software | ROTAVATA |
| Data scaling software | CCP4 ((AGROVATA) |
| Phasing software | MERLOT |
| Refinement software | X-PLOR (3.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 2.310 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Rmerge | 0.100 | 0.073 |
| Total number of observations | 24752 * | |
| Number of reflections | 12348 * | |
| <I/σ(I)> | 9.3 | |
| Completeness [%] | 93.0 | 71.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 * | 300 | Patenaude, S.I., (1998) Acta Crystallogr., Sect.D, 54, 1456. * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | Fv | 7 (mg/ml) | |
| 2 | 1 | reservoir | PEG4000 | 25-30 (%) | |
| 3 | 1 | reservoir | HEPES | 0.1 (M) | pH8.0 |
| 4 | 1 | reservoir | 10 (mM) |