1J8M

Signal Recognition Particle conserved GTPase domain from A. ambivalens

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM14
Synchrotron siteESRF
BeamlineBM14
Detector technologyIMAGE PLATE
DetectorMARRESEARCH
Spacegroup nameC 2 2 21
Unit cell lengths64.866, 128.020, 72.004
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution25.000 - 2.000
R-factor0.21916
Rwork0.216
R-free0.27002
RMSD bond length0.011

*

RMSD bond angle1.100

*

Data reduction softwareMOSFLM
Data scaling softwareCCP4 ((SCALA))
Refinement softwareREFMAC
Data quality characteristics
 Overall
Low resolution limit [Å]40.000
High resolution limit [Å]2.000
Rmerge0.051

*

Total number of observations451808

*

Number of reflections20842
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

20

*

Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein8 (mg/ml)
21reservoiracetate100 (mM)
31reservoircalcium acetate100 (mM)
41reservoirPEG800018 (%)

227111

PDB entries from 2024-11-06