Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1IQL

Human coagulation factor Xa in complex with M54476

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date1999-06-04
DetectorRIGAKU RAXIS IV
Wavelength(s)1.5418
Spacegroup nameP 21 21 21
Unit cell lengths71.880, 78.670, 55.850
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution8.000 - 2.700
Rwork0.211
R-free0.30400
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.009
RMSD bond angle1.400
Phasing softwareGLRF
Refinement softwareCNX (2000)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]2.800
High resolution limit [Å]2.7002.700
Rmerge0.0680.121
Number of reflections7552
Completeness [%]82.263.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.2293PEG1500, calcium chloride, M54476, tris-HCl, pH 7.20, VAPOR DIFFUSION, SITTING DROP, temperature 293K

221051

PDB entries from 2024-06-12