Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1IP6

G127A HUMAN LYSOZYME

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU300
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2001-03-01
DetectorRIGAKU RAXIS IV
Wavelength(s)1.5418
Spacegroup nameP 21 21 21
Unit cell lengths56.266, 61.339, 32.739
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution8.000 - 1.800
R-factor0.184
Rwork0.184
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Refinement softwareX-PLOR
Data quality characteristics
 Overall
High resolution limit [Å]1.800
Rmerge0.050
Number of reflections10384
Completeness [%]96.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.5283sodium phosphate, sodium chloride, pH 4.5, VAPOR DIFFUSION, HANGING DROP, temperature 283K

218853

PDB entries from 2024-04-24