1IP5
G105A HUMAN LYSOZYME
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU300 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2001-02-26 |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 56.379, 61.443, 32.616 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 8.000 - 1.800 |
Rwork | 0.174 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Refinement software | X-PLOR |
Data quality characteristics
Overall | |
High resolution limit [Å] | 1.800 |
Rmerge | 0.055 |
Number of reflections | 10321 |
Completeness [%] | 93.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.5 | 283 | sodium phosphate, sodium chloride, pH 4.5, VAPOR DIFFUSION, HANGING DROP, temperature 283K |