1HCK
HUMAN CYCLIN-DEPENDENT KINASE 2
Experimental procedure
| Detector technology | IMAGE PLATE |
| Detector | RIGAKU RAXIS II |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 72.820, 72.660, 54.070 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 8.000 - 1.900 |
| R-factor | 0.185 |
| Rwork | 0.185 |
| R-free | 0.27200 |
| RMSD bond length | 0.012 |
| RMSD bond angle | 24.580 * |
| Data reduction software | R-AXIS |
| Phasing software | X-PLOR (3.1) |
| Refinement software | X-PLOR (3.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | |
| High resolution limit [Å] | 1.900 | 1.900 * |
| Rmerge | 0.067 | |
| Number of reflections | 22636 | 3019 * |
| Completeness [%] | 97.3 | 92.8 * |
| Redundancy | 3.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion * | 7.4 * | 4 * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | protein | 10 (mg/ml) | |
| 2 | 1 | drop | HEPES | 10 (mM) | |
| 3 | 1 | drop | EDTA | 1 (mM) | |
| 4 | 1 | reservoir | HEPES | 200 (mM) | |
| 5 | 1 | reservoir | EDTA | 1 (mM) |