1GHF
ANTI-ANTI-IDIOTYPE GH1002 FAB FRAGMENT
Experimental procedure
| Detector technology | AREA DETECTOR |
| Detector | XUONG-HAMLIN MULTIWIRE |
| Spacegroup name | P 4 21 2 |
| Unit cell lengths | 150.400, 150.400, 43.000 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 30.000 - 2.700 |
| R-factor | 0.21 |
| Rwork | 0.210 |
| RMSD bond length | 0.017 |
| RMSD bond angle | 28.700 * |
| Data reduction software | XENGEN ((HOWARD) |
| Phasing software | X-PLOR (3.1) |
| Refinement software | X-PLOR (3.1) |
Data quality characteristics
| Overall | Outer shell | |
| High resolution limit [Å] | 2.700 * | 2.700 * |
| Rmerge | 0.076 | |
| Total number of observations | 65132 * | |
| Number of reflections | 13743 | |
| Completeness [%] | 97.0 | 92 * |
| Redundancy | 4.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | protein | 5 (mg/ml) | |
| 2 | 1 | drop | PEG3350 | 6 (%(w/v)) | |
| 3 | 1 | reservoir | PEG3350 | 12 (%) |