1GBV
(ALPHA-OXY, BETA-(C112G)DEOXY) T-STATE HUMAN HEMOGLOBIN
Experimental procedure
Detector technology | AREA DETECTOR |
Collection date | 1993-10-10 |
Detector | SIEMENS |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 63.180, 83.560, 53.730 |
Unit cell angles | 90.00, 99.60, 90.00 |
Refinement procedure
Resolution | 6.000 - 2.000 |
R-factor | 0.18 * |
Rwork | 0.184 |
RMSD bond length | 0.020 |
RMSD bond angle | 0.040 * |
Data reduction software | XENGEN |
Refinement software | PROLSQ |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 6.000 |
High resolution limit [Å] | 2.000 |
Rmerge | 0.060 |
Total number of observations | 50688 * |
Number of reflections | 34600 |
<I/σ(I)> | 2.3 |
Completeness [%] | 92.8 * |
Redundancy | 1.46 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | unknown * | 6.5 * | Perutz, M.F., (1968) J. Crystal Growth, 2, 54. * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | 1 | ammonium sulfate | 4 (M) | |
2 | 1 | 1 | 2 (M) | ||
3 | 1 | 1 | 2 (M) |