1GBU
DEOXY (BETA-(C93A,C112G)) HUMAN HEMOGLOBIN
Experimental procedure
Detector technology | AREA DETECTOR |
Collection date | 1994-11-20 |
Detector | SIEMENS |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 63.020, 82.940, 53.830 |
Unit cell angles | 90.00, 99.16, 90.00 |
Refinement procedure
Resolution | 6.000 - 1.800 |
R-factor | 0.17 * |
Rwork | 0.167 |
RMSD bond length | 0.020 * |
RMSD bond angle | 0.040 * |
Data reduction software | XENGEN |
Refinement software | PROLSQ |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 6.000 |
High resolution limit [Å] | 1.800 |
Rmerge | 0.080 * |
Total number of observations | 131074 * |
Number of reflections | 41926 |
<I/σ(I)> | 1.1 |
Completeness [%] | 82.7 |
Redundancy | 3.1 * |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | unknown * | 6.5 * | Perutz, M.F., (1968) J. Crystal Growth, 2, 54. * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | 1 | ammonium sulfate | 4 (M) | |
2 | 1 | 1 | 2 (M) | ||
3 | 1 | 1 | 2 (M) |