Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1G3Y

ARG80ALA DTXR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date1998-10-08
DetectorRIGAKU RAXIS II
Wavelength(s)1.5418
Spacegroup nameP 31 2 1
Unit cell lengths62.800, 62.800, 109.200
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution8.000 - 2.800
Rwork0.224
R-free0.32800
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.013
RMSD bond angle1.800
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareX-PLOR (3.851)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]99.0002.900
High resolution limit [Å]2.8002.800
Rmerge0.0780.326
Number of reflections6373
<I/σ(I)>17
Completeness [%]98.093.2
Redundancy4.34.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5293Ammonium sulfate, Zn2+, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K

222926

PDB entries from 2024-07-24