1G3T
CYS102SER DTXR
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 1996-12-15 |
| Detector | RIGAKU RAXIS II |
| Spacegroup name | P 32 2 1 |
| Unit cell lengths | 63.000, 63.000, 216.000 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 8.000 - 2.350 |
| Rwork | 0.238 |
| R-free | 0.31800 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.700 |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | X-PLOR (3.851) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 99.000 | 2.430 |
| High resolution limit [Å] | 2.350 | 2.350 |
| Rmerge | 0.053 | 0.360 |
| Number of reflections | 19654 | |
| <I/σ(I)> | 15.6 | |
| Completeness [%] | 90.5 | 56 |
| Redundancy | 3.9 | 1.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 298 | Ammonium sulfate, glycerol, EDTA, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |