1G3S
CYS102SER DTXR
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 298 |
| Detector technology | IMAGE PLATE |
| Collection date | 1996-11-12 |
| Detector | RIGAKU RAXIS II |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 31 2 1 |
| Unit cell lengths | 63.600, 63.600, 110.300 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 8.000 - 2.400 |
| Rwork | 0.185 |
| R-free | 0.27100 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.700 |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | X-PLOR (3.851) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 99.000 | 2.480 |
| High resolution limit [Å] | 2.400 | 2.400 |
| Rmerge | 0.061 | 0.429 |
| Number of reflections | 10070 | |
| <I/σ(I)> | 20.8 | |
| Completeness [%] | 94.5 | 95.2 |
| Redundancy | 8 | 6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 8.5 | 298 | Ammonium sulfate, EDTA, glycerol, pH 8.5, VAPOR DIFFUSION, temperature 298K |