1FHG
HIGH RESOLUTION REFINEMENT OF TELOKIN
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE BM14 |
Synchrotron site | ESRF |
Beamline | BM14 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 1997-09-01 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 63.710, 63.710, 58.860 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 20.000 - 2.000 |
R-factor | 0.233 |
Rwork | 0.210 |
R-free | 0.26600 |
Structure solution method | IR |
Starting model (for MR) | 1tlk |
RMSD bond length | 0.010 |
RMSD bond angle | 1.669 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.050 |
High resolution limit [Å] | 1.980 | 1.980 |
Rmerge | 0.070 | 0.574 |
Number of reflections | 9904 | |
<I/σ(I)> | 35.7 | 2.34 |
Completeness [%] | 99.6 | 99.6 |
Redundancy | 10.5 | 4.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4 | 273 | PEG6000, sodium acetate, pH 4.0, VAPOR DIFFUSION, SITTING DROP, temperature 273.0K |