Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1FHG

HIGH RESOLUTION REFINEMENT OF TELOKIN

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM14
Synchrotron siteESRF
BeamlineBM14
Temperature [K]100
Detector technologyCCD
Collection date1997-09-01
Spacegroup nameP 32 2 1
Unit cell lengths63.710, 63.710, 58.860
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution20.000 - 2.000
R-factor0.233
Rwork0.210
R-free0.26600
Structure solution methodIR
Starting model (for MR)1tlk
RMSD bond length0.010
RMSD bond angle1.669
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.050
High resolution limit [Å]1.9801.980
Rmerge0.0700.574
Number of reflections9904
<I/σ(I)>35.72.34
Completeness [%]99.699.6
Redundancy10.54.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4273PEG6000, sodium acetate, pH 4.0, VAPOR DIFFUSION, SITTING DROP, temperature 273.0K

227344

PDB entries from 2024-11-13

PDB statisticsPDBj update infoContact PDBjnumon