Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1EMT

FAB ANTIBODY FRAGMENT OF AN C60 ANTIFULLERENE ANTIBODY

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsSIEMENS
Temperature [K]100
Detector technologyIMAGE PLATE
DetectorMARRESEARCH
Spacegroup nameP 1 21 1
Unit cell lengths57.900, 65.745, 65.562
Unit cell angles90.00, 112.45, 90.00
Refinement procedure
Resolution60.000 - 2.250
R-factor0.18

*

Rwork0.180
R-free0.24000
RMSD bond length0.018

*

RMSD bond angle2.106

*

Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 Overall
High resolution limit [Å]2.250
Rmerge0.090
Number of reflections19413
Completeness [%]90.0
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7

*

10% PEG 8000, 0.1 M citrate, Fab at 7 mg/ml concentration, pH 5.0, VAPOR DIFFUSION, HANGING DROP
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropFab7 (mg/ml)
21dropTris10 (mM)
31reservoirPEG800010 (%)
41reservoircitrate0.1 (M)

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon