RIBOSOME RECYCLING FACTOR FROM THERMUS THERMOPHILUS

Experimental procedure
Experimental methodMAD
Source typeROTATING ANODE
Source detailsRIGAKU
Temperature [K]110
Detector technologyIMAGE PLATE
Collection date1999-07-30
DetectorRIGAKU
Spacegroup nameP 32 2 1
Unit cell lengths71.500, 71.500, 79.600
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution10.000 - 2.600
R-factor0.236
Rwork0.234
R-free0.30700
Structure solution methodMAD
RMSD bond length0.007
RMSD bond angle1.100
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareMLPHARE
Refinement softwareCNS (1.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.660
High resolution limit [Å]2.6002.600
Rmerge0.0380.234
Total number of observations28513

*

Number of reflections7568

*

<I/σ(I)>17.6
Completeness [%]99.798.7
Redundancy3.81.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.6

*

293ammonium sulphate, sodium acetate, MES, pH 4.9, VAPOR DIFFUSION, HANGING DROP, temperature 20K
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein10-15 (mg/ml)
21reservoirammonium sulfate2 (M)
31reservoirsodium acetate trihydrate0.1 (M)

222926