1CYJ
CYTOCHROME C6
Experimental procedure
Detector technology | IMAGE PLATE |
Collection date | 1993-01-22 |
Detector | RIGAKU RAXIS IIC |
Spacegroup name | I 2 3 |
Unit cell lengths | 81.600, 81.600, 81.600 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 10.000 - 1.900 |
R-factor | 0.187 |
Rwork | 0.187 |
RMSD bond length | 0.018 |
RMSD bond angle | 1.665 |
Data reduction software | R-AXIS |
Phasing software | X-PLOR (3.1) |
Refinement software | X-PLOR (3.1) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 57.600 |
High resolution limit [Å] | 1.900 |
Rmerge | 0.072 |
Number of reflections | 5709 |
Completeness [%] | 78.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | protein | 8.8 (mg/ml) | |
2 | 1 | reservoir | MES | 25 (mM) | |
3 | 1 | reservoir | PEG3350 | 25 (%) | |
4 | 1 | reservoir | 150 (mM) |