1CV7
Crystal structure of enhanced cyan-emission variant of GFP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU300 |
Temperature [K] | 298 |
Detector technology | IMAGE PLATE |
Collection date | 1999-06-06 |
Detector | RIGAKU RAXIS IV |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 52.052, 62.781, 66.830 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.500 - 2.500 |
R-factor | 0.1861 |
Rwork | 0.186 |
RMSD bond length | 0.013 |
RMSD bond angle | 2.400 |
Data scaling software | SCALEPACK |
Phasing software | TNT |
Refinement software | TNT |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.500 | 2.560 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.121 | 0.611 |
Number of reflections | 7829 | |
<I/σ(I)> | 2.93 | |
Completeness [%] | 97.4 | 95.5 |
Redundancy | 6.9 | 6.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.6 | 298 | 12% PEG-1550, 50mM calcium acetate and 100 mM acetaete buffer, pH 4.6, VAPOR DIFFUSION, HANGING DROP, temperature 298.0K |