Experimental procedure
Source typeSYNCHROTRON
Source detailsSRS BEAMLINE PX7.2
Synchrotron siteSRS
BeamlinePX7.2
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date1995-06-20
DetectorMAR scanner 180 mm plate
Spacegroup nameP 1 21 1
Unit cell lengths38.890, 79.680, 68.520
Unit cell angles90.00, 104.91, 90.00
Refinement procedure
Resolution8.000 - 2.100
R-factor0.212
Rwork0.212
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.015
RMSD bond angle1.900
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareX-PLOR
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.150
High resolution limit [Å]2.0002.000
Rmerge0.0470.115
Total number of observations95102

*

Number of reflections27439
<I/σ(I)>24.19.7
Completeness [%]99.298
Redundancy3.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

6

*

Banfield, M.J., (1996) Acta Cryst. D., 52, 1107.

*

Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein10 (mg/ml)
21dropBis-Tris20 (mM)
31reservoirPEG400017-21 (%)
41reservoirsodium acetate50 (mM)

222926