1CG2
CARBOXYPEPTIDASE G2
Experimental procedure
Source type | SYNCHROTRON |
Source details | SRS BEAMLINE PX9.5 |
Synchrotron site | SRS |
Beamline | PX9.5 |
Temperature [K] | 293 |
Detector technology | IMAGE PLATE |
Collection date | 1996-04-18 |
Detector | MARRESEARCH |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 81.260, 105.280, 122.190 |
Unit cell angles | 90.00, 109.54, 90.00 |
Refinement procedure
Resolution | 20.000 - 2.500 |
R-factor | 0.196 |
Rwork | 0.196 |
R-free | 0.22400 |
Structure solution method | MIR |
RMSD bond length | 0.007 |
RMSD bond angle | 24.310 * |
Data reduction software | MOSFLM |
Data scaling software | CCP4 |
Phasing software | X-PLOR (3.1) |
Refinement software | X-PLOR (3.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.630 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.069 | 0.168 |
Total number of observations | 224872 * | |
Number of reflections | 62936 | |
<I/σ(I)> | 6.41 | 4 |
Completeness [%] | 93.9 | 90.4 |
Redundancy | 3.57 | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.2 | 291 | HANGING DROPS WERE FORMED BY MIXING 4 MICROLITERS OF PROTEIN SOLUTION AT 16-20 MG/ML WITH 4 MICROLITERS OF RESERVOIR SOLUTION CONTAINING 10-12% PEG 4000, 0.2M TRIS (PH 7.2), 0.2M ZINC ACETATE 10% GLYCEROL. CRYSTALS GREW AT 18-20 DEGREES WITHIN A FEW DAYS., vapor diffusion - hanging drop, temperature 291K |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | enzyme | 8-10 (mg/ml) | |
2 | 1 | drop | PEG4000 | 5-6 (%(w/v)) | |
3 | 1 | drop | zinc acetate | 100 (mM) | |
4 | 1 | drop | Tris-HCl | 100 (mM) | |
5 | 1 | drop | glycerol | 5 (%(v/v)) | |
6 | 1 | reservoir | PEG4000 | 10-12 (%(w/v)) | |
7 | 1 | reservoir | zinc acetate | 200 (mM) | |
8 | 1 | reservoir | Tris-HCl | 200 (mM) | |
9 | 1 | reservoir | glycerol | 10 (%(v/v)) |