1C9X
H119A VARIANT OF RIBONUCLEASE A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 275 |
Detector technology | AREA DETECTOR |
Collection date | 1998-05-28 |
Detector | SIEMENS HI-STAR |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 64.530, 64.530, 65.040 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 30.000 - 1.800 |
RMSD bond length | 0.011 |
RMSD bond angle | 17.919 * |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | TNT |
Refinement software | TNT |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.900 |
High resolution limit [Å] | 1.800 | 1.800 |
Rmerge | 0.033 | 0.149 |
Total number of observations | 68047 * | |
Number of reflections | 23009 | |
<I/σ(I)> | 19 | |
Completeness [%] | 94.0 | 90 |
Redundancy | 3.0 * | 2.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 20 * | 29% ammonium sulfate, 45% sodium chloride, 100mM sodium acetate, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | sodium acetate | 0.050 (M) | |
2 | 1 | drop | protein | 30 (mg/ml) | |
3 | 1 | drop | 22.5 (%(v/v)sat) | ||
4 | 1 | drop | ammonium sulfate | 14.5 (%(v/v)sat) | |
5 | 1 | reservoir | sodium acetate | 0.10 (M) | |
6 | 1 | reservoir | 45 (%(v/v)sat) | ||
7 | 1 | reservoir | ammonium sulfate | 29 (%(v/v)sat) |