1C0Q
COMPLEX OF VANCOMYCIN WITH 2-ACETOXY-D-PROPANOIC ACID
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X12B |
Synchrotron site | NSLS |
Beamline | X12B |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 1997-05-05 |
Detector | MAR scanner 300 mm plate |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 28.400, 28.400, 65.730 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.000 - 1.000 |
R-factor | 0.119 |
Rwork | 0.119 |
R-free | 0.13900 |
RMSD bond length | 0.019 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Refinement software | SHELXL |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 1.040 |
High resolution limit [Å] | 1.000 | 1.000 |
Rmerge | 0.054 | 0.055 |
Total number of observations | 178175 * | |
Number of reflections | 13845 | |
<I/σ(I)> | 34.7 | |
Completeness [%] | 92.0 | 65 |
Redundancy | 11.8 | 2.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.6 | 291 | Sodium chloride, 2-acetoxy-D-propanoic acid, pH 4.6, vapor diffusion/hanging drop, temperature 291K |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | protein | 30 (mg/ml) | |
2 | 1 | reservoir | ligand | 100 (mM) | |
3 | 1 | reservoir | 2.0-2.4 (M) |