1BXK
DTDP-GLUCOSE 4,6-DEHYDRATASE FROM E. COLI
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 270 |
Detector technology | AREA DETECTOR |
Collection date | 1997-10-15 |
Detector | BRUKER |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 68.400, 109.200, 128.700 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.000 - 1.900 |
Rwork | 0.195 |
Structure solution method | MIR |
RMSD bond length | 0.014 |
RMSD bond angle | 2.338 |
Data reduction software | XDS |
Data scaling software | XSCALIBRE |
Refinement software | TNT (5E) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.990 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.068 | 0.260 |
Number of reflections | 73785 | |
<I/σ(I)> | 12.7 | 1.6 |
Completeness [%] | 96.0 | 86 |
Redundancy | 5.3 | 2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 6 | 15% PEG 8000 100 MM K/MES PH 6.0 |