1AND
ANIONIC TRYPSIN MUTANT WITH ARG 96 REPLACED BY HIS
Experimental procedure
| Source type | ROTATING ANODE |
| Source details | RIGAKU RUH2R |
| Temperature [K] | 273 |
| Detector technology | AREA DETECTOR |
| Collection date | 1992 |
| Detector | SIEMENS |
| Spacegroup name | I 2 3 |
| Unit cell lengths | 124.380, 124.380, 124.380 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 7.000 - 2.300 |
| R-factor | 0.161 |
| Rwork | 0.161 |
| RMSD bond length | 0.013 |
| RMSD bond angle | 2.900 |
| Data reduction software | BUDDHA |
| Data scaling software | BUDDHA |
| Refinement software | X-PLOR |
Data quality characteristics
| Overall | |
| High resolution limit [Å] | 2.300 |
| Rmerge | 0.070 * |
| Total number of observations | 26500 * |
| Number of reflections | 13200 |
| Redundancy | 2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion, hanging drop * | 8 | pH 8.0 |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | reservoir | 22 (%(w/v)) | ||
| 2 | 1 | reservoir | Tris-HCl | 20 (mM) |