1AJH
PHOTOPRODUCT OF CARBONMONOXY MYOGLOBIN AT 40 K
Experimental procedure
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X26C |
Synchrotron site | NSLS |
Beamline | X26C |
Temperature [K] | 40 |
Detector technology | IMAGE PLATE |
Collection date | 1993-06-30 |
Detector | FUJI |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 63.450, 30.440, 34.130 |
Unit cell angles | 90.00, 105.70, 90.00 |
Refinement procedure
Resolution | 10.000 - 1.690 |
R-factor | 0.171 |
Rwork | 0.171 |
R-free | 0.23400 |
Structure solution method | DIFFERENCE FOURIER |
Starting model (for MR) | 1krn |
RMSD bond length | 0.014 |
RMSD bond angle | 18.800 * |
Data reduction software | DENZO |
Data scaling software | CCP4 |
Phasing software | X-PLOR |
Refinement software | X-PLOR |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 27.500 | 1.770 |
High resolution limit [Å] | 1.690 | 1.690 |
Rmerge | 0.050 | 0.146 |
Total number of observations | 51604 * | |
Number of reflections | 13618 | |
<I/σ(I)> | 10.9 | 5 |
Completeness [%] | 95.8 | 83.5 |
Redundancy | 3.3 | 2.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | unknown * | 6 | Kendrew, J.C., (1956) Proc. Royal Soc. A, 238, 305. * |