1A7X
FKBP12-FK1012 COMPLEX
Experimental procedure
| Source type | ROTATING ANODE |
| Source details | RIGAKU RUH2R |
| Temperature [K] | 294 |
| Detector technology | AREA DETECTOR |
| Collection date | 1995-04-10 |
| Detector | XUONG-HAMLIN MULTIWIRE |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 133.590, 40.510, 93.130 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 8.000 - 2.000 |
| R-factor | 0.173 * |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1fkf |
| RMSD bond length | 0.010 |
| RMSD bond angle | 2.800 |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | X-PLOR (3.0) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 20.000 |
| High resolution limit [Å] | 2.000 |
| Rmerge | 0.046 * |
| Number of reflections | 15896 |
| <I/σ(I)> | 14 |
| Completeness [%] | 91.0 |
| Redundancy | 2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.6 | drop contains equal volume of the reservoir solution * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | protein | 10 (mg/ml) | |
| 2 | 1 | drop | Tris-HCl | 10 (mM) | |
| 3 | 1 | reservoir | sodium formate | 5.1 (M) | |
| 4 | 1 | reservoir | sodium acetate | 0.1 (M) |