Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1YGT

Dynein Light Chain TcTex-1

Experimental procedure
Experimental methodMAD
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X4A
Synchrotron siteNSLS
BeamlineX4A
Temperature [K]100
Detector technologyCCD
Collection date2000-09-04
DetectorADSC QUANTUM 4
Wavelength(s)0.99187, 0.97950, 0.97897, 0.96672
Spacegroup nameP 32 2 1
Unit cell lengths60.598, 60.598, 48.485
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution6.000 - 1.700
R-factor0.2
Rwork0.193
R-free0.23500
Structure solution methodMAD
RMSD bond length0.014
RMSD bond angle0.033
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareSHARP
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.760
High resolution limit [Å]1.7001.700
Rmerge0.0550.198
Number of reflections10932
<I/σ(I)>37.612
Completeness [%]93.896.9
Redundancy88
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION9.52930.1M CHES, pH 9.5, 2.4 M (NH4)2SO4 and 0.1M Li2SO4, vapor diffusion, temperature 293K
1VAPOR DIFFUSION9.52930.1M CHES, pH 9.5, 2.4 M (NH4)2SO4 and 0.1M Li2SO4, vapor diffusion, temperature 293K
1VAPOR DIFFUSION9.52930.1M CHES, pH 9.5, 2.4 M (NH4)2SO4 and 0.1M Li2SO4, vapor diffusion, temperature 293K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon