1WQV
Human Factor Viia-Tissue Factor Complexed with propylsulfonamide-D-Thr-Met-p-aminobenzamidine
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE BL-6B |
| Synchrotron site | Photon Factory |
| Beamline | BL-6B |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2000-03-07 |
| Detector | RIGAKU |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 71.390, 82.420, 123.510 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.990 - 2.500 |
| Rwork | 0.218 |
| R-free | 0.27200 |
| Structure solution method | FOURIER SYNTHESIS |
| Starting model (for MR) | 1dan |
| RMSD bond length | 0.005 |
| RMSD bond angle | 1.300 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | CNX (2002) |
| Refinement software | CNX (2002) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 40.000 |
| High resolution limit [Å] | 2.400 |
| Rmerge | 0.073 |
| Number of reflections | 27554 |
| Completeness [%] | 93.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5 | 298 | PEG 5000, sodium chloride, cacodylate, calcium chloride, pH 5.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |