1WBI
AVR2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-1 |
Synchrotron site | ESRF |
Beamline | ID14-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-04-16 |
Detector | ADSC CCD |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 97.669, 99.936, 135.191 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 81.650 - 1.400 |
R-factor | 0.175 |
Rwork | 0.174 |
R-free | 0.20100 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1vyo |
RMSD bond length | 0.015 |
RMSD bond angle | 1.697 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | REFMAC (5.2.0005) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 25.000 | 1.500 |
High resolution limit [Å] | 1.400 | 1.400 |
Rmerge | 0.070 | 0.550 |
Number of reflections | 257876 | |
<I/σ(I)> | 14 | 3 |
Completeness [%] | 99.6 | 99 |
Redundancy | 6 | 5.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |