Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1W7A

ATP bound MutS

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-2
Synchrotron siteESRF
BeamlineID14-2
Temperature [K]100
Detector technologyCCD
Collection date2000-11-10
DetectorADSC CCD
Spacegroup nameP 21 21 21
Unit cell lengths90.636, 93.040, 262.592
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution20.000 - 2.270
R-factor0.217
Rwork0.216
R-free0.25300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1e3m
RMSD bond length0.013
RMSD bond angle1.294
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareAMoRE
Refinement softwareREFMAC (5.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.380
High resolution limit [Å]2.3002.300
Rmerge0.0800.770
Number of reflections99607
<I/σ(I)>13.51.3
Completeness [%]99.699.6
Redundancy7.54.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
17.512-14% PEG6000, 150-300MM NACL, 10 MM MGCL2, 25 MM HEPES PH 7.5, 100 UM ADP

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon