1VWT
T STATE HUMAN HEMOGLOBIN [ALPHA V96W], ALPHA AQUOMET, BETA DEOXY
Experimental procedure
| Source type | ROTATING ANODE |
| Source details | RIGAKU RUH2R |
| Temperature [K] | 293 |
| Detector technology | AREA DETECTOR |
| Collection date | 1995-02 |
| Detector | SIEMENS |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 63.271, 83.416, 53.799 |
| Unit cell angles | 90.00, 99.54, 90.00 |
Refinement procedure
| Resolution | 25.000 - 1.900 |
| R-factor | 0.169 |
| Rwork | 0.169 |
| Structure solution method | DIFFERENCE FOURIER |
| Starting model (for MR) | 1dxu |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.200 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | X-PLOR (3.851) |
| Refinement software | X-PLOR (3.851) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 25.000 | 1.990 |
| High resolution limit [Å] | 1.900 | 1.900 |
| Rmerge | 0.067 | |
| Number of reflections | 39687 | |
| Completeness [%] | 91.3 | 75.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 |