1UVS
BOVINE THROMBIN--BM51.1011 COMPLEX
Experimental procedure
Source type | ROTATING ANODE |
Source details | RIGAKU RUH2R |
Temperature [K] | 283 |
Detector technology | AREA DETECTOR |
Detector | SIEMENS |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 81.684, 81.684, 186.400 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 8.000 - 2.800 |
R-factor | 0.208 |
Rwork | 0.208 |
R-free | 0.28000 |
RMSD bond length | 0.004 |
RMSD bond angle | 24.300 * |
Data reduction software | PROTEIN |
Data scaling software | SAINT |
Phasing software | X-PLOR |
Refinement software | X-PLOR |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 22.000 |
High resolution limit [Å] | 2.800 |
Rmerge | 0.079 |
Number of reflections | 7921 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion * | 6.9 * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | thrombin | 10 (mg/ml) | |
10 | 1 | reservoir | PEG4000 | 30 (%) | |
2 | 1 | drop | citrate | 25 (mM) | |
3 | 1 | drop | EDTA | 1 (mM) | |
4 | 1 | drop | DMSO | 10 (mM) | |
5 | 1 | drop | lithium sulfate | 0.2 (M) | |
6 | 1 | drop | Tris | 0.1 (M) | |
7 | 1 | drop | PEG4000 | 30 (%) | |
8 | 1 | reservoir | lithium sulfate | 0.2 (M) | |
9 | 1 | reservoir | Tris | 0.1 (M) |