Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1UMY

BHMT from rat liver

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM14
Synchrotron siteESRF
BeamlineBM14
Temperature [K]100
Detector technologyCCD
Collection date2001-04-15
Spacegroup nameP 1 21 1
Unit cell lengths57.830, 149.270, 96.250
Unit cell angles90.00, 92.92, 90.00
Refinement procedure
Resolution48.400 - 2.500
R-factor0.253
Rwork0.253
R-free0.29100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1lt8
RMSD bond length0.009
RMSD bond angle1.400
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareAMoRE
Refinement softwareCNS (1.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.0002.580
High resolution limit [Å]2.5002.500
Rmerge0.0880.460
Number of reflections58532
<I/σ(I)>6.51.5
Completeness [%]99.799.1
Redundancy44
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
18.516% PEG 1500, PH=8.5, pH 8.50

220113

PDB entries from 2024-05-22

PDB statisticsPDBj update infoContact PDBjnumon