1UG3

C-terminal portion of human eIF4GI

Experimental procedure
Experimental methodMAD
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 32-ID
Synchrotron siteAPS
Beamline32-ID
Temperature [K]110
Detector technologyCCD
Collection date2000-02-19
Wavelength(s)0.964
Spacegroup nameP 1 21 1
Unit cell lengths78.618, 50.567, 99.895
Unit cell angles90.00, 101.59, 90.00
Refinement procedure
Resolution30.000 - 2.240
R-factor0.247
Rwork0.244
R-free0.29200
Structure solution methodMAD
RMSD bond length0.006
RMSD bond angle1.180
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareSHARP
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0002.310
High resolution limit [Å]2.2402.240
Number of reflections36093
<I/σ(I)>9
Completeness [%]96.495
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.527730% PEG MME 5000, 0.1M MES, 0.2M AMMONIUM SULFATE, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 277.0K