1TWM
Interleukin-1 Beta Mutant F146Y
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Temperature [K] | 298 |
Detector technology | IMAGE PLATE |
Collection date | 2000-01-31 |
Detector | RIGAKU |
Wavelength(s) | 1.5418 |
Spacegroup name | P 43 |
Unit cell lengths | 54.890, 54.890, 77.250 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 77.300 - 2.260 |
R-factor | 0.1763 |
Rwork | 0.175 |
R-free | 0.18990 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 77.300 |
High resolution limit [Å] | 2.260 |
Number of reflections | 10788 |
Completeness [%] | 99.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.4 | 298 | 29% W/V AMMONIUM SULFATE, 100 mM Tris, pH 7.4, VAPOR DIFFUSION, HANGING DROP, temperature 298K |