1TOO
Interleukin 1B Mutant F146W
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU |
| Temperature [K] | 298 |
| Detector technology | IMAGE PLATE |
| Collection date | 1999-11-11 |
| Detector | RIGAKU RAXIS II |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 43 |
| Unit cell lengths | 54.950, 54.950, 77.250 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 77.250 - 2.100 |
| R-factor | 0.186 |
| Rwork | 0.185 |
| R-free | 0.19900 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | CNS |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 77.250 |
| High resolution limit [Å] | 2.100 |
| Number of reflections | 13286 |
| Completeness [%] | 98.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.4 | 298 | 29% AMMONIUM SULFATE W/V, 100 MM Tris , pH 7.4, VAPOR DIFFUSION, HANGING DROP, temperature 298K |