1KPC
PKCI-1-APO+ZINC
Experimental procedure
| Source type | SYNCHROTRON |
| Source details | NSLS BEAMLINE X4A |
| Synchrotron site | NSLS |
| Beamline | X4A |
| Temperature [K] | 110 |
| Detector technology | IMAGE PLATE |
| Collection date | 1995-09-06 |
| Detector | FUJI |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 63.940, 78.660, 46.310 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 7.000 - 2.200 |
| R-factor | 0.217 |
| Rwork | 0.217 |
| R-free | 0.30900 |
| RMSD bond length | 0.018 |
| RMSD bond angle | 25.444 * |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | X-PLOR (3.1) |
| Refinement software | X-PLOR (3.1) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 64.000 |
| High resolution limit [Å] | 1.800 |
| Rmerge | 0.058 |
| Total number of observations | 82407 * |
| Number of reflections | 36570 |
| Completeness [%] | 86.3 |
| Redundancy | 2.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion, hanging drop * | 6.5 * | 20 * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | reservoir | PEG8000 | 13-18 (%) | |
| 2 | 1 | reservoir | sodium cacodylate | 100 (mM) | |
| 3 | 1 | drop | apo-PKCI-1 | 10 (mg/ml) | |
| 4 | 1 | drop | zinc-PKCI-1 | 0.1 (mM) |