Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1JHF

LEXA G85D MUTANT

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X12B
Synchrotron siteNSLS
BeamlineX12B
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date1995-01-01
DetectorMARRESEARCH
Wavelength(s)1.08
Spacegroup nameP 43 21 2
Unit cell lengths90.020, 90.020, 102.820
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution15.000 - 1.800
R-factor0.24

*

Rwork0.240
R-free0.26300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1jhc
RMSD bond length0.008
RMSD bond angle1.350
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareCNS (1.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.860
High resolution limit [Å]1.8001.800
Rmerge0.0480.433
Total number of observations143898

*

Number of reflections38550

*

3638

*

<I/σ(I)>28.43.7
Completeness [%]96.8

*

93.8

*

Redundancy3.73.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.82931.8 M ammonium sulfate, 0.1 M BIS-Tris buffer, pH 6.8, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11reservoirammonium sulfate1.8 (M)
21reservoirBis-Tris propane0.1 (M)

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon