Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1IQE

Human coagulation factor Xa in complex with M55590

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date1999-01-12
DetectorRIGAKU RAXIS IV
Wavelength(s)1.5418
Spacegroup nameP 21 21 21
Unit cell lengths72.490, 78.650, 55.750
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution8.000 - 2.900
Rwork0.213
R-free0.29700
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.300
Phasing softwareGLRF
Refinement softwareCNX (2000)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]3.000
High resolution limit [Å]2.9002.900
Rmerge0.0860.121
Number of reflections6142
Completeness [%]81.959.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.2293PEG1500, calcium chloride, M55590, tris-HCl, pH 7.2, VAPOR DIFFUSION, SITTING DROP, temperature 293K

219869

PDB entries from 2024-05-15