1HU9
LIPOXYGENASE-3 (SOYBEAN) COMPLEX WITH 4-HYDROPEROXY-2-METHOXY-PHENOL
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 295 |
| Detector technology | IMAGE PLATE |
| Collection date | 1999-08-01 |
| Detector | RIGAKU RAXIS IV |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 112.790, 137.320, 61.870 |
| Unit cell angles | 90.00, 95.55, 90.00 |
Refinement procedure
| Resolution | 40.000 - 2.200 |
| R-factor | 0.185 |
| Rwork | 0.185 |
| R-free | 0.27100 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1lnh |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.600 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | X-PLOR |
| Refinement software | X-PLOR (3.851) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 40.000 | 2.280 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Rmerge | 0.070 | 0.331 |
| Number of reflections | 45106 | |
| <I/σ(I)> | 13.1 | 1 |
| Completeness [%] | 95.5 | 90.9 |
| Redundancy | 3 | 2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 5.3 | 296 | PEG 8000, phosphate-citrate buffer, sodium azide, pH 5.3, VAPOR DIFFUSION, SITTING DROP, temperature 296K |