1G3S
CYS102SER DTXR
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 298 |
Detector technology | IMAGE PLATE |
Collection date | 1996-11-12 |
Detector | RIGAKU RAXIS II |
Wavelength(s) | 1.5418 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 63.600, 63.600, 110.300 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 8.000 - 2.400 |
Rwork | 0.185 |
R-free | 0.27100 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.700 |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | X-PLOR (3.851) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 99.000 | 2.480 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmerge | 0.061 | 0.429 |
Number of reflections | 10070 | |
<I/σ(I)> | 20.8 | |
Completeness [%] | 94.5 | 95.2 |
Redundancy | 8 | 6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 8.5 | 298 | Ammonium sulfate, EDTA, glycerol, pH 8.5, VAPOR DIFFUSION, temperature 298K |