1EOO

ECORV BOUND TO COGNATE DNA

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL1-5
Synchrotron siteSSRL
BeamlineBL1-5
Temperature [K]100
Detector technologyCCD
Collection date1999-04-19
DetectorOTHER
Spacegroup nameC 2 2 21
Unit cell lengths72.600, 120.400, 182.700
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution4.800 - 2.160
R-factor0.2285
Rwork0.231
R-free0.31600
RMSD bond length0.012
RMSD bond angle2.100
Data reduction softwareMOSFLM
Data scaling softwareCCP4 ((TRUNCATE))
Phasing softwareX-PLOR
Refinement softwareX-PLOR
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.220
High resolution limit [Å]2.1602.160
Rmerge0.0480.315
Total number of observations50635

*

Number of reflections21638
<I/σ(I)>9.1
Completeness [%]82.081.5
Redundancy1.81.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion

*

7.5

*

297drop consists of equal volume of protein and reservoir solutions

*

Crystallization Reagents
IDcrystal IDsolution IDreagent nameconcentrationdetails
111(NH4)2SO4
212(NH4)2SO4
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropEcoRV10 (mg/ml)
21dropDNA1.5-fold molar excess
31reservoirammonium sulfate1.5 (M)

219869

PDB entries from 2024-05-15