1D4S
HIV-1 PROTEASE V82F/I84V DOUBLE MUTANT/TIPRANAVIR COMPLEX
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | SIEMENS |
Temperature [K] | 298 |
Detector technology | AREA DETECTOR |
Collection date | 1995-06-11 |
Detector | SIEMENS |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 58.730, 86.680, 46.210 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 10.000 - 2.500 |
R-free | 0.29400 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | X-GEN |
Data scaling software | X-GEN |
Phasing software | MERLOT |
Refinement software | SHELXL-97 |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 10.000 | 2.660 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.130 | 0.396 |
Number of reflections | 8612 | |
<I/σ(I)> | 4.9 | 1.9 |
Completeness [%] | 100.0 | 99.5 |
Redundancy | 3.4 | 2.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 5.4 | none * |