15C8
CATALYTIC ANTIBODY 5C8, FREE FAB
Experimental procedure
Source type | ROTATING ANODE |
Source details | MACSCIENCE M06X |
Temperature [K] | 293 |
Detector technology | AREA DETECTOR |
Collection date | 1996-11 |
Detector | SIEMENS |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 201.000, 80.500, 39.300 |
Unit cell angles | 90.00, 98.70, 90.00 |
Refinement procedure
Resolution | 30.000 - 2.500 |
R-factor | 0.19 |
Rwork | 0.190 |
R-free | 0.25100 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1dbb |
RMSD bond length | 0.006 |
RMSD bond angle | 1.300 |
Data reduction software | XENGEN |
Data scaling software | XENGEN |
Phasing software | AMoRE |
Refinement software | X-PLOR (3.851) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.590 |
High resolution limit [Å] | 2.500 | 2.500 |
Number of reflections | 20624 | |
<I/σ(I)> | 17.7 | 1.6 |
Completeness [%] | 95.6 | 84.1 |
Redundancy | 2.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 5.5 | pH 5.5 |