Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 5.0.1 |
| Synchrotron site | ALS |
| Beamline | 5.0.1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-10-28 |
| Detector | DECTRIS PILATUS 2M |
| Wavelength(s) | 1.00 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 57.275, 74.032, 106.800 |
| Unit cell angles | 90.00, 93.68, 90.00 |
Refinement procedure
| Resolution | 60.800 - 2.300 |
| R-factor | 0.2099 |
| Rwork | 0.207 |
| R-free | 0.26550 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.001 |
| RMSD bond angle | 0.400 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21.2_5419) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 60.800 | 2.430 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Rmerge | 0.140 | |
| Number of reflections | 20402 | 130 |
| <I/σ(I)> | 4.3 | 1.7 |
| Completeness [%] | 90.9 | |
| Redundancy | 2 | |
| CC(1/2) | 0.990 | 0.530 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 293 | 12% PEG4000, 0.1M Tris pH8.5, 0.1M NaI |