8GV0
Crystal structure of anti-FIXa IgG fab without FAST-Ig mutations
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PHOTON FACTORY BEAMLINE BL-1A |
Synchrotron site | Photon Factory |
Beamline | BL-1A |
Temperature [K] | 95 |
Detector technology | PIXEL |
Collection date | 2021-12-13 |
Detector | DECTRIS EIGER X 4M |
Wavelength(s) | 1.04500 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 40.937, 162.082, 139.014 |
Unit cell angles | 90.00, 98.05, 90.00 |
Refinement procedure
Resolution | 42.500 - 3.192 |
R-factor | 0.2015 |
Rwork | 0.196 |
R-free | 0.30980 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5dk3 |
RMSD bond length | 0.009 |
RMSD bond angle | 1.160 |
Data reduction software | XDS (Jan 31, 2020) |
Data scaling software | Aimless (0.7.7) |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 137.644 | 137.644 | 3.705 |
High resolution limit [Å] | 3.192 | 10.268 | 3.192 |
Rmerge | 0.521 | 0.123 | 1.376 |
Rmeas | 0.563 | 0.132 | 1.487 |
Rpim | 0.212 | 0.049 | 0.557 |
Total number of observations | 127817 | 6486 | 6171 |
Number of reflections | 18205 | 909 | 911 |
<I/σ(I)> | 4.1 | 11.31 | 1.64 |
Completeness [%] | 86.4 | 99.6 | 37.7 |
Completeness (spherical) [%] | 61.0 | 99.6 | 8.5 |
Completeness (ellipsoidal) [%] | 86.4 | 99.6 | 37.7 |
Redundancy | 7.02 | 7.14 | 6.77 |
CC(1/2) | 0.929 | 0.988 | 0.552 |
Anomalous completeness (spherical) | 60.4 | 99.9 | 8.1 |
Anomalous completeness | 86.0 | 99.9 | 36.6 |
Anomalous redundancy | 3.6 | 3.7 | 3.5 |
CC(ano) | 0.000 | -0.016 | -0.018 |
|DANO|/σ(DANO) | 0.8 | 0.7 | 0.8 |
Diffraction limits | Principal axes of ellipsoid fitted to diffraction cut-off surface |
3.186 Å | 0.936, 0.936, 0.936 |
3.842 Å | 0.000, 0.000, 0.000 |
3.782 Å | 0.353, 0.353, 0.353 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 20.0 %w/v Polyethylene glycol 3350 [PEG 3350], 0.1 M CBTP buffer [CBTP] pH 6.4 |